HUBUNGAN KELENGKAPAN DUST COLLECTOR DAN LAMA OPERASIONAL DENGAN KONSENTRASI PM2,5 DAN PM10 DI SEKITAR ASPHALT MIXING PLANT, KOTA PALANGKA RAYA
Adi Kusuma1), Deddy Nan Setya Putra Tanggara1), Subrata Aditama Kittie Aidon Uda1), Theresia Susi1), Kartika Bungas1), Moch. Anwar1)
Keywords:
Keywords: asphalt mixing plant; dust collector; linear regression; PM10; PM2.5Abstract
Asphalt mixing plants (AMP) release particulate matter that degrades ambient air quality, and the dust collector (DC) is the main component for controlling it. This study was conducted to evaluate the completeness of DC components and to analyze the relationship of DC completeness and operating duration with PM2.5 and PM10 concentrations at two AMPs in Palangka Raya City, Indonesia, namely PT. Karya Halim Sampoerna with a complete DC and PT. Ganisha Dwi Utama with an incomplete DC lacking a water tank, water pump, water sprayer, and wet scrubber. Concentrations were recorded for each hour of seven hours of operation using a direct reading air quality detector. Descriptive statistics and simple linear regression were applied. The mean PM2.5 and PM10 concentrations were 38.6 and 50.0 µg/m³ at the AMP with a complete DC and 191.4 and 250.7 µg/m³ at the AMP with an incomplete DC, about five times higher. DC completeness was strongly associated with concentrations (R² = 0.818 for PM2.5 and 0.819 for PM10; p < 0.001). Operating duration showed opposite trends: concentrations increased by about 84% over seven hours at the incomplete DC (p < 0.01) but decreased by 56% to 57% at the complete DC (p < 0.01). Because DC completeness was confounded with site, date, and weather, the results are interpreted as associations. Complete installation of DC components, routine maintenance, and periodic 24 hour monitoring with meteorological records are recommended.
Keywords: asphalt mixing plant; dust collector; linear regression; PM10; PM2.5

